Carel Clima Manuale Utente

Navigare online o scaricare Manuale Utente per Termostati Carel Clima. Carel Clima User manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - User manual

climaUser manualthermostat/humidistat

Pagina 2

10ENGclima +030220641 - rel. 1.3 - 18.04.20132.3 Electrical connections:125678910GAnalog outputPowersupplyOutput 2G0NTC ext.Digital inputG024V1VA,50/6

Pagina 3 - DISPOSAL

11ENGclima +030220641 - rel. 1.3 - 18.04.20133. USER INTERFACE AND MODES3.1 Display and buttonsThe  gures below show the display and the representa

Pagina 4

12ENGclima +030220641 - rel. 1.3 - 18.04.2013The values displayed in the LARGE and SMALL  elds (Fig. 3.b) depend on the setting of parameter dyS, as

Pagina 5 - Contents

13ENGclima +030220641 - rel. 1.3 - 18.04.20134. CONFIGURATIONS4.1 Con guring the operating modesBefore closing the instrument again, the chosen mod

Pagina 6

14ENGclima +030220641 - rel. 1.3 - 18.04.20134.3 Additional functionsThe controller, as well as the control algorithms for the various types of appli

Pagina 7 - 1. INTRODUCTION

15ENGclima +030220641 - rel. 1.3 - 18.04.2013Functions that can be associated with the digital inputAccording to the model chosen, the digital input c

Pagina 8 - Table of hardware codes:

16ENGclima +030220641 - rel. 1.3 - 18.04.2013Average of the temperature readings between the built-in sensor and the remote sensorThis operating mode

Pagina 9 - 2. INSTALLATION

17ENGclima +030220641 - rel. 1.3 - 18.04.2013Control the outputs via RS485 serial connectionThe status of the analogue output and the relays on the in

Pagina 10 - 2.3 Electrical connections:

18ENGclima +030220641 - rel. 1.3 - 18.04.2013PasswordOn all models a password (PS) can be set for accessing the parameters. Once the value of PS has b

Pagina 11 - 3. USER INTERFACE AND MODES

19ENGclima +030220641 - rel. 1.3 - 18.04.2013This chapter describes the temperature and humidity control modes available.The control modes for the di

Pagina 13 - 4. CONFIGURATIONS

20ENGclima +030220641 - rel. 1.3 - 18.04.2013Parameters involved:Code Description Default LEValue or link if LE = 1day set point in cooling 24.0 °C 1

Pagina 14 - 4.2 Main parameters to be set

21ENGclima +030220641 - rel. 1.3 - 18.04.20135.5 (T2 + H) two-stage temperature and humidity controlThis is used in applications with two outputs dedi

Pagina 15 - AUTO humidity control

22ENGclima +030220641 - rel. 1.3 - 18.04.2013Con guration 2 (AdC = 2) - DiP 4 has no e ectUsed to control a classic system with air-conditioner/heat

Pagina 16 - Tab. 4.j

23ENGclima +030220641 - rel. 1.3 - 18.04.2013Con guration 1 (AdC =1) - DiP 4 has no e ectThe typical application is the control of a classic system

Pagina 17 - Tab. 4.l

24ENGclima +030220641 - rel. 1.3 - 18.04.20135.8 (T+H radiant ON/OFF) ON/OFF mode for radiant  oor systems ON/OFF control mode in radiant systems is

Pagina 18 - Antifreeze

25ENGclima +030220641 - rel. 1.3 - 18.04.2013Control calculation:1. Based on the proportional error (Temperature measured – set point) and the integr

Pagina 19 - Tab. 5.a

26ENGclima +030220641 - rel. 1.3 - 18.04.20136. TABLE OF PARAMETERS6.1 Description of the parameters for the standard version The parameters availab

Pagina 20 - 5.3 (H) humidity control

27ENGclima +030220641 - rel. 1.3 - 18.04.2013code parameter range default UOM noteCStParameter for set point compensationParameter CSt enables and set

Pagina 21 - DIP 4=OFF

28ENGclima +030220641 - rel. 1.3 - 18.04.2013code parameter range default UOM noteLInInstrument output control modeEnabling this parameter allows the

Pagina 22

29ENGclima +030220641 - rel. 1.3 - 18.04.20136.2 Additional parameters, available in version T+H for proportional control of radiant systems (cod. AD

Pagina 23

3ENGclima +030220641 - rel. 1.3 - 18.04.2013IMPORTANTCAREL bases the development of its products on decades of experience in HVAC, on the continuous i

Pagina 24

30ENGclima +030220641 - rel. 1.3 - 18.04.20138. TECHNICAL SPECIFICATIONS8.1 Technical speci cationsPower supply24 Vac +10 to -15%, 50/60Hz, 1 VA24

Pagina 25 - Control calculation:

31ENGclima +030220641 - rel. 1.3 - 18.04.20139. APPENDIX9.1 Supervisor parameters for CAREL and Modbus® protocolUnit code 57 (all codes except for A

Pagina 26 - 6. TABLE OF PARAMETERS

32ENGclima +030220641 - rel. 1.3 - 18.04.2013par “CAREL sup index”“Modbus index”description min max def UOM R/W note- 37 36 “Status of EEProm alarm 0=

Pagina 27

33ENGclima +030220641 - rel. 1.3 - 18.04.2013par.CAREL sup. indexModbus® indexdescription min max def. UOM R/Wnote- 15 43 PWM value for heating 0 100

Pagina 28

34ENGclima +030220641 - rel. 1.3 - 18.04.2013Unit code 58 (code ADCF000610 only)Digital variablespar “CAREL sup index”“Modbus index”description min ma

Pagina 29 - 7. ALARMS AND SIGNALS

35ENGclima +030220641 - rel. 1.3 - 18.04.2013par “CAREL sup index”“Modbus index”description min max def UOM R/W note- 40 39 “Low water temperature ala

Pagina 30 - 8. TECHNICAL SPECIFICATIONS

36ENGclima +030220641 - rel. 1.3 - 18.04.2013par.CAREL sup. indexModbus® indexdescription min max def. UOM R/Wnote 26 2 night temperature set point in

Pagina 31 - Digital variables

37ENGclima +030220641 - rel. 1.3 - 18.04.2013Note

Pagina 35

CAREL INDUSTRIES HQsVia dell’Industria, 11 - 35020 Brugine - Padova (Italy)Tel. (+39) 049.9716611 - Fax (+39) 049.9716600e-mail: [email protected] - w

Pagina 36 - 9.2 Software updates

5ENGclima +030220641 - rel. 1.3 - 18.04.2013Contents1. INTRODUCTION 71.1 Models available ...

Pagina 38

7ENGclima +030220641 - rel. 1.3 - 18.04.20131. INTRODUCTIONThe CLIMA thermostat-humidistat terminal is an instrument that can, according to the model

Pagina 39

8ENGclima +030220641 - rel. 1.3 - 18.04.2013Table of hardware codes:Purchase code Hardware features Functions performedADCA000100Standard thermostat2

Pagina 40 - Agenzia/Agency:

9ENGclima +030220641 - rel. 1.3 - 18.04.20132. INSTALLATIONBelow is a description of the recommended operations for correct installation.2.1 Assembl

Commenti su questo manuale

Nessun commento